VM2D.0/-L24型德國(guo)HYDAC壓(ya)差開(kai)關的工作(zuo)原(yuan)理:
德國(guo)HYDAC壓(ya)差開(kai)關的閥(fa)體和(he)行(xing)程(cheng)開關組(zu)裝在壹(yi)塊(kuai)底板上。潤(run)滑脂(zhi)在壓(ya)力的作(zuo)用(yong)下(xia)從(cong)主(zhu)管道B進(jin)入(ru)德國(guo)HYDAC壓(ya)差開(kai)關閥(fa)體活塞(sai)的右(you)腔,主(zhu)管道A卸荷。壹(yi)旦兩(liang)條主管道的壓(ya)差達(da)到(dao)設定(ding)值(zhi),活塞(sai)克服(fu)左(zuo)腔內(nèi)彈簧(huang)力(li)向(xiang)左移(yi)動,並(bing)推動行程(cheng)開關(guan),使觸點1和2閉合,發(fā)(fa)出(chu)脈沖訊號(hao)至(zhi)系統(tǒng)(tong)電(dian)控(kong)箱,責令(ling)換(huan)向(xiang)閥(fa)換(huan)向(xiang),這(zhe)時主(zhu)管道A受(shou)壓(ya),B卸荷,活塞(sai)在二(er)端腔內(nèi)彈簧(huang)的作(zuo)用(yong)下(xia)對(dui)中(zhong),行(xing)程開關觸點1和2斷開(kai),觸橋(qiao)處中(zhong)位(wei)。
系統(tǒng)(tong)開(kai)始(shi)第(di)二(er)周期(qi)工作(zuo),壹(yi)旦主管道A和(he)B間(jian)壓(ya)差又(you)達到(dao)設定(ding)值(zhi)時,活塞(sai)向(xiang)右(you)移動,行程(cheng)開關(guan)觸點3和4閉合,脈(mai)沖訊號(hao)再(zai)次使系(xi)統(tǒng)(tong)中(zhong)的換(huan)向(xiang)閥(fa)換(huan)向(xiang),開始(shi)下次循(xun)環(huán)工作(zuo)。
德國(guo)HYDAC壓(ya)差開(kai)關在HVAC系(xi)統(tǒng)(tong)中(zhong)的應用(yong)主(zhu)要(yao)是(shi)根據(jù)HVAC設備(bei)的阻力與流(liu)量(liang)曲(qu)線進(jin)行控(kong)制(zhi)的,HVAC中(zhong)的水側換(huan)熱(re)器(qi)(套管式、殼(ke)管式、管板式和常(chang)用(yong)的板式換(huan)熱(re)器(qi))、水(shui)過(guo)濾(lv)器(qi)、閥(fa)門(men)和水泵(beng)等(deng)都(dou)有其(qi)壓(ya)降(jiang)與流(liu)量(liang)的性(xing)能曲(qu)線,只(zhi)要(yao)將德國(guo)HYDAC壓(ya)差開(kai)關兩(liang)側的測(ce)量(liang)壓(ya)差與預先設定(ding)值(zhi)進行(xing)比較(jiao),就(jiu)可(ke)以(yi)準(zhun)確控(kong)制(zhi)流(liu)量(liang)。
德國(guo)HYDAC壓(ya)差開(kai)關是(shi)壹(yi)種(zhong)特殊的控(kong)制(zhi)開關,它(ta)是(shi)依(yi)據(jù)相互(hu)部(bu)件(jian)間(jian)的壓(ya)力差值(zhi)並(bing)依(yi)靠(kao)電(dian)信(xin)號(hao)進行信(xin)息傳(chuan)遞控(kong)制(zhi)開關閉合(he)或(huo)打(da)開的壹(yi)類開關。總的來說(shuo)就(jiu)是(shi)利(li)用(yong)兩(liang)條管道的壓(ya)差來(lai)發(fā)出(chu)電(dian)訊號(hao),當系列(lie)液管二端的壓(ya)差升(sheng)高(gao)(或(huo)降(jiang)低(di))而超(chao)過(guo)控(kong)制(zhi)器(qi)設定(ding)值(zhi)時,發(fā)(fa)出(chu)信(xin)號(hao)以(yi)控(kong)制(zhi)換(huan)向(xiang)閥(fa)換(huan)向(xiang)或(huo)監(jiān)(jian)視潤(run)滑系(xi)統(tǒng)(tong)。則(ze)閥(fa)門(men)進而開(kai)大(或(huo)關(guan)小(xiao)),從(cong)而(er)系(xi)統(tǒng)(tong)液(ye)管二端的壓(ya)差減(jian)小(xiao),達到(dao)系統(tǒng)(tong)的正常運行。
德國(guo)HYDAC壓(ya)差開(kai)關可廣(guang)泛應用(yong)在使用(yong)板(ban)式換(huan)熱(re)器(qi)、套管式換(huan)熱(re)器(qi)和(he)殼(ke)管式換(huan)熱(re)器(qi)的大中(zhong)小(xiao)型風(feng)冷(leng)或(huo)水(shui)冷冷水(shui)機(ji)組(zu)中(zhong)作(zuo)水(shui)流(liu)量(liang)控(kong)制(zhi)及水(shui)泵(beng)和水(shui)過(guo)濾(lv)器(qi)狀(zhuang)態(tài)(tai)的監(jiān)控(kong)。也(ye)同(tong)時應用(yong)於氣(qi)體檢測(ce)、非(fei)腐蝕性(xing)介(jie)質(zhì)(zhi)、測(ce)量(liang)絕壓(ya)、表(biao)壓(ya),廣泛應用(yong)在空(kong)調(diào)(tiao)和(he)潔(jie)凈室(shi)、風(feng)扇和(he)過(guo)濾(lv)器(qi)的吹風(feng)控(kong)制(zhi)、流(liu)體和(he)液(ye)位(wei)控(kong)制(zhi)。
封(feng)蓋(gai)安(an)裝好之(zhi)前不(bu)要(yao)測(ce)試(shi)。否(fou)則不(bu)小(xiao)心碰到(dao)帶電(dian)部(bu)分(fen)會引(yin)起(qi)短路。緩慢(man)增(zeng)加壓(ya)力/壓(ya)差,必(bi)要(yao)時使用(yong)測(ce)試(shi)儀器(qi),當壓(ya)力/壓(ya)差增(zeng)加到(dao)設定(ding)值(zhi)時,開(kai)關(guan)動作(zuo)。再(zai)緩慢(man)降(jiang)低(di)壓(ya)力,到(dao)設定(ding)值(zhi)時,開(kai)關(guan)恢(hui)復(fu)(要(yao)註(zhu)意該(gai)產(chǎn)品(pin)的回差特(te)性(xing))。如(ru)動作(zuo)正確,說明開(kai)關安(an)裝及壓(ya)力/電(dian)氣(qi)連(lian)接正常。
實物如(ru)下圖(tu)所示(shi):