意(yi)大利歐瑪(ma)爾OMAL氣(qi)動(dong)閥(fa)如何(he)安裝(zhuang)使(shi)用
東(dong)莞廣聯工(gong)業(yè)自動(dong)化設(she)備(bei)有(you)限(xian)公(gong)司(si)專業(yè)供應(ying)歐瑪(ma)爾OMAL氣(qi)動(dong)閥(fa),歐瑪(ma)爾OMAL執(zhí)(zhi)行器等全(quan)系(xi)列產品。公(gong)司(si)具有(you)良(liang)好(hao)的市場信譽(yu),專業(yè)的銷售(shou)和技術(shu)服務(wu)團(tuan)隊,憑(ping)著多(duo)年經營經驗,熟悉(xi)並了解(jie)市場行情,贏(ying)得(de)了國內外(wai)廠商的信任與(yu)支持(chi)*!
意(yi)大利歐瑪(ma)爾OMAL氣(qi)動(dong)閥(fa)的安裝與(yu)使(shi)用
(1)氣動(dong)閥(fa)在(zai)安裝(zhuang)使(shi)用之前,必(bi)須(xu)對(dui)閥(fa)門進(jin)行安(an)裝(zhuang)前的檢查和開關(guan)運(yun)行試(shi)驗。只(zhi)有(you)在(zai)運(yun)行動(dong)作(zuo)正常(chang)的條件(jian)下(xia),才能安(an)裝使(shi)用。
(2)氣動(dong)閥(fa)的安裝要(yao)盡(jin)可能使(shi)閥(fa)門與(yu)管(guan)路(lu)法蘭(lan)同心(xin),並加支撐固(gu)定(ding)。不(bu)能使(shi)球(qiu)閥(fa)受其(qi)它(ta)外(wai)力作(zuo)用,以(yi)免(mian)損(sun)壞(huai)閥(fa)門的中密封及閥(fa)門變(bian)形(xing)。造成閥(fa)門開(kai)關(guan)不(bu)靈及閥(fa)門的損壞而(er)無法(fa)使(shi)用。
(3)要(yao)保證(zheng)氣球(qiu)閥(fa)及氣(qi)動(dong)元件(jian)所(suo)提供(gong)的動(dong)力氣(qi)源(yuan)必(bi)須(xu)是潔凈,盡(jin)可能不(bu)帶(dai)油汙(wu)及水。清(qing)潔度應(ying)小(xiao)於0.4微米。
(4)接(jie)入(ru)氣(qi)源(yuan)之前,必(bi)須(xu)清(qing)潔供氣(qi)管(guan)路(lu),氣源(yuan)接口(kou)和開關(guan)等器件,以(yi)防(fang)由於管(guan)路(lu)不(bu)清(qing)潔帶(dai)上(shang)汙(wu)物和泥(ni)沙(sha)沖入(ru)氣(qi)動(dong)執(zhí)(zhi)行單元而(er)造成(cheng)故(gu)障(zhang)。
(5)氣(qi)動(dong)執(zhí)(zhi)行器、電磁(ci)閥(fa)、定(ding)位(wei)器、過濾(lv)器、減壓閥(fa)等的連接,可用銅管(guan)或尼(ni)龍(long)管(guan),為以(yi)防(fang)防(fang)塵(chen)及減(jian)小(xiao)噪(zao)聲,排(pai)氣口應安裝消聲(sheng)器或消聲(sheng)節(jié)(jie)流閥(fa)。
(6)安裝好(hao)以(yi)後(hou),對(dui)氣動(dong)閥(fa)門應(ying)進(jin)行試(shi)驗,給氣動(dong)執(zhí)(zhi)行器加壓至額(e)定(ding)值(zhi),壓力為0.4~0.7mpa,對(dui)氣動(dong)球(qiu)閥(fa)進(jin)行開(kai)關(guan)試驗,觀(guan)察(cha)閥(fa)門的開閉情況(kuang)。應(ying)轉(zhuan)動(dong)靈活(huo)無(wu)卡(ka)阻現象(xiang)。在(zai)開關(guan)如有(you)卡阻現象(xiang)可增高氣壓,反(fan)復(fu)開(kai)關使閥(fa)門調(tiao)到(dao)開(kai)關靈(ling)活(huo)即(ji)可。
(7)安裝調(tiao)試(shi)開關型(xing)氣動(dong)閥(fa)時(shi),先用手動(dong)裝置(zhi)進(jin)行(電(dian)磁(ci)閥(fa)上的手動(dong)按鈕(niu))調(tiao)試(shi)、動(dong)作(zuo)正常(chang)後(hou)在(zai)通電調(tiao)試(shi)。
(8)氣動(dong)閥(fa)應定(ding)期(qi)進(jin)行維(wei)護保養(yǎng)閥(fa)桿轉(zhuan)動(dong)處,應(ying)三(san)個月(yue)加油(機油)壹(yi)次(ci)。定(ding)期(qi)對(dui)氣動(dong)執(zhí)(zhi)行單元和配合(he)使用的空氣過濾(lv)器進(jin)行放(fang)水、排汙(wu)。正常(chang)的情況(kuang)下(xia)六個(ge)月(yue)檢(jian)查壹(yi)次(ci),每(mei)年(nian)檢(jian)修(xiu)壹(yi)次(ci)。
歐瑪(ma)爾OMAL氣(qi)動(dong)閥(fa)的調(tiao)試(shi)方法
氣動(dong)閥(fa)門定(ding)位(wei)器是氣(qi)動(dong)控(kong)制閥(fa)重(zhong)要(yao)的氣動(dong)附件(jian)之(zhi)壹(yi),實(shi)現著接(jie)收控(kong)制信號(hao)準確定(ding)位(wei)閥(fa)門行程位置(zhi)的作(zuo)用。
氣動(dong)閥(fa)門定(ding)位(wei)器功能:氣(qi)動(dong)閥(fa)門定(ding)位(wei)器與(yu)氣(qi)動(dong)執(zhí)(zhi)行機(ji)構(gou)共(gong)同構(gou)成(cheng)自控(kong)單元和各種調(tiao)節(jié)(jie)閥(fa)連接經過調(tiao)試(shi)安裝後(hou),組(zu)合(he)成(cheng)氣動(dong)調(tiao)節(jié)(jie)閥(fa)。氣動(dong)閥(fa)門定(ding)位(wei)器用於各種工(gong)業(yè)自動(dong)化過程控(kong)制領(ling)域當中(zhong)。
氣(qi)動(dong)控(kong)制閥(fa)出廠時(shi),定(ding)位(wei)器與(yu)控(kong)制閥(fa)都(dou)做(zuo)過(guo)標定(ding),但(dan)是閥(fa)門裝(zhuang)到(dao)管(guan)線上(shang)後(hou)往(wang)往(wang)需(xu)要(yao)再進(jin)行壹(yi)次(ci)標定(ding),常(chang)規(guī)的標定(ding)方法是:標定(ding)5點即(ji)4mA,8mA,12mA,16mA,20mA,在(zai)12mA時(shi)定(ding)位(wei)器反(fan)饋桿處於水平位(wei)置(zhi),其(qi)它(ta)幾組(zu)信(xin)號(hao)時(shi)閥(fa)門位(wei)置(zhi)應(ying)分別(bie)在(zai)0,25%,75%,100%的行程處,且(qie)反(fan)饋桿的轉(zhuan)動(dong)角(jiao)度小(xiao)於正負45度(du)。對(dui)於零(ling)點和滿(man)度的偏(pian)差可單獨調(tiao)整(zheng)相(xiang)應(ying)螺釘(ding)進(jin)行修(xiu)正,正常(chang)情況(kuang)下(xia)如果閥(fa)門行程和給定(ding)信(xin)號(hao)壹(yi)壹(yi)對(dui)應則(ze)表(biao)示標定(ding)完(wan)成。
閥(fa)門關(guan)閉(bi)時(shi)產生(sheng)的壹(yi)個(ge)主(zhu)要(yao)問題是如何(he)達到(dao)使(shi)閥(fa)門嚴(yan)密(mi)關(guan)閉的閥(fa)座全(quan)負荷(he)。通常(chang)的方法是對(dui)閥(fa)門進(jin)行標定(ding),從而(er)使閉(bi)合(he)部件(jian)(如閥(fa)塞(sai)、隔膜、閥(fa)板等)恰好(hao)定(ding)位(wei)在(zai)閥(fa)座上,而(er)不(bu)是確認閉(bi)合(he)部件(jian)是否*靠(kao)在(zai)閥(fa)座上。為了保持設(she)計泄漏(lou)量,避免密(mi)封表(biao)面受到(dao)腐(fu)蝕(shi),必(bi)須(xu)設(she)計適(shi)當(dang)的密封負荷(he)。
單作(zuo)用氣動(dong)執(zhí)(zhi)行器通常(chang)都(dou)采(cai)用薄(bo)膜式(shi)設(she)計。采用這種設(she)計方式,使用的彈簧可以(yi)減(jian)少(shao)閥(fa)座負荷(he),也(ye)可以(yi)承(cheng)受(shou)全(quan)部閉(bi)合(he)壓力。典型(xing)的雙(shuang)作(zuo)用氣動(dong)執(zhí)(zhi)行器采用活塞(sai)設(she)計。采用這種設(she)計方式,與(yu)薄(bo)膜式(shi)設(she)計型(xing)不(bu)同,供(gong)應壓力不(bu)需(xu)要(yao)進(jin)行限(xian)制,為了達到(dao)較(jiao)高(gao)的閉合壓力,可以(yi)應(ying)用全(quan)負荷(he)供(gong)應(ying)壓力。對(dui)於活(huo)塞(sai)設(she)計型(xing),壓力越高,閥(fa)門的穩(wěn)定(ding)性(xing)與(yu)控(kong)制靈敏(min)度就(jiu)越好(hao)
歐瑪(ma)爾OMAL氣(qi)動(dong)閥(fa)的性能檢(jian)測
1、閥(fa)門某(mou)壹(yi)規(guī)格批(pi)量制造時(shi),應委托(tuo)性機(ji)構(gou)進(jin)行以(yi)下(xia)性(xing)能的檢測:
①閥(fa)門在(zai)工壓狀況(kuang)下(xia)的啟閉力矩(ju);
②在(zai)工壓狀況(kuang)下(xia),能保證(zheng)閥(fa)門關(guan)閉(bi)嚴(yan)密的連續(xù)啟(qi)閉(bi)次數(shu);
③閥(fa)門在(zai)管(guan)道(dao)輸水狀況(kuang)下(xia)的流阻系(xi)數(shu)的檢測。
2、閥(fa)門在(zai)出廠前應進(jin)行以(yi)下(xia)的檢測:
①閥(fa)門在(zai)開啟(qi)狀(zhuang)況(kuang)下(xia),閥(fa)體(ti)應承(cheng)受(shou)閥(fa)門工(gong)壓值二(er)倍(bei)的內壓檢測;
②閥(fa)門的關閉狀況(kuang)下(xia),兩(liang)側(ce)分別承受1.1倍(bei)閥(fa)門工(gong)壓值,無(wu)滲漏(lou);但(dan)金(jin)屬(shu)密(mi)封的蝶閥(fa),滲漏(lou)值(zhi)亦不(bu)大於相(xiang)關(guan)要(yao)求。